GX3232 Series
|
-
|
16-Bit Multi-Function PXI Cards with A/D, D/A and Digital I/O Channels
|
|
Product InfoSpecification
Ordering
|  | 32 single-ended or 16 differential, 16-bit, scanned analog inputs |
|  | 300 KS per second aggregate analog input sampling rate |
|  | 4 analog outputs, 300 KS per second analog output clocking rate per channel |
|  | 16-bit, bi-directional digital port with two auxiliary I/O lines |
|  | +/- 10V, +/- 5V, +/- 2.5V input / output ranges |
|  | 32K sample input and output FIFO data buffers |
|  | 3U Compact PCI form factor |
|  | Supplied with all master TS700 (GBATS) test systems as a PMC board |
|
DescriptionThe GX3232 is a multi-channel 16-bit, analog input and output cPCI module, supporting 32 single-ended or 16 differential input channels and four analog output channels. The inputs can be software configured for differential or single-end operation and are sequentially scanned with maximum aggregate scan rate of 300 KS/s. Input ranges are software-selectable as ±10V, ±5V or ±2.5V. Four analog output channels provide software-selectable output ranges of ±2.5V, ±5V or ±10V. The outputs can be updated either synchronously or asynchronously and support waveform generation. Each output can be clocked at rates up to 300 KS/s. A 16-bit digital I/O port is also provided, which supports 16 bidirectional data lines. Note that when used with a GBATS system only 8 of these digital I/O lines are available at the GBATS’ receiver interface.
FeaturesThe GX3232’s input channels are sampled sequentially at maximum aggregate rate of 300 KS/s. Sampled data is accessed via the PCI bus and a 32K-sample FIFO buffer. Scanned channels can be set for 2, 4, 8, 16, or 32 channels per scan with the sample clock being generated by one of two internal rate generators which employ 16-bit programmable dividers. The four output channels can be clocked at rates up to 300 KS/s and like the input channels, offer programmable ranges. Each output channel includes a dedicated 16-bit D/A converter with output data being clocked from a 32K sample FIFO buffer, which interfaces to the PCI bus. Output clocking is generated by one of two internal rate generators which employ 16-bit programmable dividers. Sync input and sync output lines are also provided for synchronizing the input and output signals to an external event. These signals are not accessible at the GBATS’ receiver interface.
The module supports an auto-calibration routine which applies any required offset and gain correction values for all input and output channels. Additionally, a self-test input switching network routes output channels or calibration reference signals to the analog inputs – verifying module integrity and functionality.
SoftwareThe GX3232 is supplied with a virtual instrument panel, which includes a 32-bit DLL driver library and documentation. The virtual panel can be used to interactively adjust and control the instrument from a window that displays the instrument’s current settings and measurements.
Applications |  | Automotive testing |
|  | High-performance baseband testing |
|  | Medical device and module test |
|  | ATE systems |
See Also
|  | GX1642 - Analog Output PXI Card | |  | GX1648 - Analog Output PXI Card |
|
| Analog Inputs | | Input Channels | 32 single-ended or 16 differential (software configurable) | | Input Voltage Ranges | +/- 10 V, +/- 5 V, +/- 2.5 V FS (software configurable) | | Input Impedence | 2 Megaohms, differential 1 Megaohm to ground, single-ended | | Bias Current | 80 nA max. | | Full Scale DC Accuracy | +/- 4.2 mV, 10 volt range +/- 2.8 mV, 5 volt range +/- 2.0 mV, 2.5 volt range | | A to D Converter | | Resolution | 16 bits | | Maximum Conversion Rate | 300 KS/s | | Channels per Scan | 2, 4, 8, 16, or 32 per scan | | Maximum Scan Rate | 75 KS/s in multiple channel mode 150 KS/s in 2 channel mode 300 KS/s in single-channel mode | | Minimum Scan Rate | 400 scans per second (single-rate generator) .0075 scans per second (two-rate generators) | | Clock Source | 24 MHz oscillator, two 16 dividers (independent or cascadable) | | Memory | 32K sample FIFO | | Analog Output Channels | | Configuration | Four single-ended | | Output Range | +/- 10 V, +/- 5 V, +/- 2.5 V FS (software configurable) | | Output Impedence | 1 ohm max. | | Output Current | +/- 3 mA max. | | Full Scale DC Accuracy | +/- 3.0 mV, 10 volt range +/- 2.2 mV, 5 volt range +/- 1.7 mV, 2.5 volt range (no load) | | Settling Time | 8 us to on LSB, typical with 50% full scale step | | D to A Converter | | Resolution | 16 bits | | Sampling Rate | 400 S/s to 300 KS/s using internal-rate generator DC to 300 KS/s with hardware or software sync | | Clock Source | Internal (programmable), software, external sync | | Internal Clock | 3 to 1 MHz sample rate, 24 bit divider from master clock frequency | | Clocking Modes | Continuous, periodic clocking, triggered burst | | Memory | 32K sample FIFO | | Digital Input/Output | | Configuration | 16 TTL I/O lines organized as two bytes, configurable as inputs or outputs | | Output Drive | 20 mA, source or sink | | Control | Register read/write | | General | | Mating I/O Connector | 68 pin, dual-ribbon socket Robinson Nugent P50E-068-S-TG or equivalent | | Current Consumption | +5 V @ 1.5 A max. | | Size | 3U, single slot | | Temperature Operating | 0° C to 65° C | | Storage | -40° C to +85° C | | Humidity (Non-Condensing) | 0% to 80% (operating) |
|
Note: Specifications are subject to change without notice.
|
|
|

|
|